The 375 A problem
Power is volts times amps. That is the whole article, but the consequences are worth spelling out, because they are the single most common source of disappointment at a fast charger.
A station has two ceilings, not one. It has the power rating painted on the side, and it has a current limit set by the cable and its connector. The plugs on this site are real cable sizes, each rated at what its cable carries at 1,000 V: 40, 80, 125, 150, 200, 250, 375, 500 and 800 A, so 40 to 800 kW. 375 A is the largest air-cooled CCS1 cable made for continuous use; 500 and 800 A are liquid-cooled. The current does not appear on the sign. (Several of these cables can boost higher for a while, but for a time the maker does not state, so the calculator uses the continuous figure.)
The arithmetic
A 400 V-class pack is not at 400 V. It sits somewhere around 345 V when nearly empty and 390 V when nearly full. Multiply:
345 V x 375 A = 129 kW
390 V x 375 A = 146 kW
So a 400 V car on a 375 A cable is physically capped somewhere around 129 to 146 kW, no matter what the station is rated for. A Tesla Model 3 Long Range has a curve that peaks at 250 kW. It never sees it on that hardware. It peaks at 138 kW and the station is not even trying hard.
What this does to the price list
A station built from 30 kW power modules at 270, 330 or 360 kW is too big for the 250 A cable and not big enough to need a liquid-cooled one, so it gets the same 375 A cable as the 375 kW plug. Here is the same car, the same 10 to 80% session, on four stations whose stickers differ by 105 kW (the calculator’s Custom rating builds the first three):
| Station | Peak reached | 10 to 80% |
|---|---|---|
| 270 kW | 138 kW | 27 min |
| 330 kW | 138 kW | 27 min |
| 360 kW | 138 kW | 27 min |
| 375 kW | 138 kW | 27 min |
Four price tiers, one result. They all carry the same 375 A cable, and 375 A is 375 A. If you are choosing between a 270 and a 375 kW station in a 400 V car, you are choosing between two identical experiences.
What a bigger cable buys
For a 400 V car the only thing that helps is more current:
| Plug | Peak reached | 10 to 80% |
|---|---|---|
| 200 kW, 200 A | 77 kW | 44 min |
| 375 kW, 375 A | 138 kW | 27 min |
| 500 kW, 500 A | 180 kW | 24 min |
| 800 kW, 800 A | 250 kW | 23 min |
On the 800 A cable the Model 3 finally reaches its own 250 kW peak, and from there its curve is the limit, not the plug. That takes a liquid-cooled cable, which is heavier, dearer and needs a chiller in the station.
The way out is voltage, not amps
An 800 V pack draws the same power at half the current. At 700 V, 375 A is 262 kW:
700 V x 375 A = 262 kW
That is the entire argument for 800 V architecture. It is not that the cells are better. It is that the cable between the station and the car has a fixed current limit, and doubling the voltage doubles the power you can push through it. Every 800 V car on this site keeps gaining as the cable grows, right up until its own curve becomes the limit. Every 400 V car flattens at its cable and stops caring.
Even an 800 V car cannot use all of a 375 kW plug, though: that would take the full 1,000 V, which no pack here reaches. The next step up is a liquid-cooled 500 or 800 A cable, and for trucks, the megawatt charging system.
Where to see it
Open the calculator, pick a Model 3 and the 375 kW plug, and read the callout under the main chart. Then switch to an Ioniq 5 without touching anything else. Same station, same session window, 118 kW more power and ten minutes less time, entirely because of pack voltage.
There is one more twist, which is that Tesla built its cabinets the other way round: around 700 A at only 500 V. That is Supercharger reality.
Next
Supercharger reality: 700 A at 500 V
Tesla went high-current and low-voltage, which is why a 400 V Tesla really does see 250 kW, and why an 800 V car plugged into one has to split its pack.